{"id":973,"date":"2022-10-04T13:49:47","date_gmt":"2022-10-04T13:49:47","guid":{"rendered":"https:\/\/vanselectroengineerings.com\/?page_id=973"},"modified":"2022-10-18T16:09:41","modified_gmt":"2022-10-18T16:09:41","slug":"segments-3-phase-to-2-phase-1-phase-gang-operated-vcb-selector","status":"publish","type":"page","link":"https:\/\/vanselectroengineerings.com\/index.php\/segments-3-phase-to-2-phase-1-phase-gang-operated-vcb-selector\/","title":{"rendered":"Segments- 3-PHASE TO 2-PHASE\/1-PHASE GANG OPERATED VCB SELECTOR"},"content":{"rendered":"<p><section class=\"kc-elm kc-css-959327 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-678940 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-854443 kc_text_block\"><\/p>\n<p><strong>3-PHASE TO 2-PHASE\/1-PHASE GANG OPERATED VCB SELECTOR<\/strong><\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-2096 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-48092 kc_col-sm-8 kc_column kc_col-sm-8\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-745357 kc_text_block\"><\/p>\n<p>\u2022 The VCB Selector Switch consists of 2 Nos. of gang-operated, 3 pole Auto Recloser type VCBs<\/p>\n<p>\u2022 One gang operated VCB will switch ON for extending 3-phase supply and the other gang operated VCB will Switch ON for extending 2 phase\/1-Phase supply.<\/p>\n<p>\u2022 The two outgoing lines which are to be extended the same phase supply during 2 phase\/1-Phase feed shall be mechanically linked at the incoming side of the 2-phase\/1 Phase feed VCB.<\/p>\n<p>\u2022 Mechanical and electrical interlocks are provided between the two VCBs, to prevent simultaneous closing of both the VCBs.<\/p>\n<p>\u2022 However, it is possible to keep both the VCBS OFF at the same time.<\/p>\n<p>\u2022 The VCB Selector Switch will be operated On-load<\/p>\n<p>\u2022 The operating mechanism is magnetic actuator<\/p>\n<p>\u2022 Compact and light-weight<\/p>\n<p>\u2022 Robust construction<\/p>\n<p>\u2022 Suitable for Outdoor Duty, protected to Degree of Protection IP55.<\/p>\n<p>\u2022 It is possible to install the VCB Selector Switch in an existing Pole\/Structure<\/p>\n<p>\n<\/div><\/div><\/div><div class=\"kc-elm kc-css-694288 kc_col-sm-4 kc_column kc_col-sm-4\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-102895 kc_shortcode kc_single_image\">\n\n        <img src=\"https:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/Screenshot-2022-10-05-145145.png\" class=\"\" alt=\"\" \/>    <\/div>\n<div class=\"kc-elm kc-css-779928 kc_text_block\"><\/p>\n<p>3-Phase to 2-Phase Gang Opearted VCB Selector<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-393291 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-254645 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-683592\" style=\"height: 20px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-504722 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-569329 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-564780 kc_shortcode kc_single_image\">\n\n        <img src=\"https:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/2-2.png\" class=\"\" alt=\"\" \/>    <\/div>\n<div class=\"kc-elm kc-css-140540 kc_text_block\"><\/p>\n<p>3-Phase to 1-Phase Gang Operated VCB Selector<\/p>\n<p>\n<\/div><\/div><\/div><div class=\"kc-elm kc-css-878446 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-215193 kc_text_block\"><\/p>\n<p>\u2022The VCB Selector Switch will be electrically operated, with a provision for manual tripping<\/p>\n<p>\u2022The insulation medium is solid dielectric &amp; the interruption medium is vacuum<\/p>\n<p>\u2022 SCADA\/DMS compatible<\/p>\n<p>\u2022 Mechanical and electrical ON\/OFF indications<\/p>\n<p>\u2022 The control cabinet suitable for outdoor duty, with\u00a0 \u00a0 IP55 degree of protection, and of light weight and\u00a0 \u00a0 is suitable for Pole\/Structure mounting<\/p>\n<p>\u2022 The Incoming as well as Outgoing Bushings of the VCB Selector Switch are of universal type, suitable for terminating ACSR OH Conductor or Aluminium\/Copper Cable<\/p>\n<p>\u2022The VCB Selector Switch has an in-built comprehensive Protection Unit, with a set of suitably rated integral Current Transformers, embedded in the VCB bushings.<\/p>\n<p>\u2022Flexible Protection Options &#8211; from basic Overcurrent &amp; Earthfault Relay to comprehensive Feeder Manager<\/p>\n<p>\u2022Optional Metering &#8211; from basic ammeter to comprehensive communicable multi-function meter<\/p>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-953652 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-714858 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-83673\" style=\"height: 34px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-280891 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-249663 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-223880\" style=\"height: 40px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-628525 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-253609 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-460362 kc_text_block\"><\/p>\n<p class=\"elementor-heading-title elementor-size-default\"><strong>Guaranteed Technical Particulars<\/strong><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-150498 kc_text_block\"><\/p>\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-69b8605 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" data-id=\"69b8605\" data-element_type=\"section\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4dca69b\" data-id=\"4dca69b\" data-element_type=\"column\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-9e77877 elementor-widget elementor-widget-heading\" data-id=\"9e77877\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n<div class=\"elementor-widget-container\">\n<table>\n<thead>\n<tr>\n<th class=\"elementor-repeater-item-71558f7\" colspan=\"1\">PARAMETER<\/th>\n<th class=\"elementor-repeater-item-fafbbc0\" colspan=\"1\">12kV<\/th>\n<th class=\"elementor-repeater-item-e5cc378\" colspan=\"1\">24kV<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"elementor-repeater-item-ba66086\">\n<th class=\"elementor-repeater-item-b10191b\" colspan=\"1\" rowspan=\"1\">Rated Voltage (kV)<\/th>\n<td class=\"elementor-repeater-item-6040715\" colspan=\"1\" rowspan=\"1\">12<\/td>\n<td class=\"elementor-repeater-item-3c0d9b5\" colspan=\"1\" rowspan=\"1\">24<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-43453e1\">\n<th class=\"elementor-repeater-item-48da52a\" colspan=\"1\" rowspan=\"1\">Rated Frequency (Hz.)<\/th>\n<td class=\"elementor-repeater-item-c2b42b8\" colspan=\"1\" rowspan=\"1\">50\/60<\/td>\n<td class=\"elementor-repeater-item-c1ead63\" colspan=\"1\" rowspan=\"1\">50\/60<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-a82922f\">\n<th class=\"elementor-repeater-item-6cef8c9\" colspan=\"1\" rowspan=\"1\">Rated Current (A)<\/th>\n<td class=\"elementor-repeater-item-c66a8e0\" colspan=\"1\" rowspan=\"1\">1250<\/td>\n<td class=\"elementor-repeater-item-94f02ed\" colspan=\"1\" rowspan=\"1\">1250<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-1007f5b\">\n<th class=\"elementor-repeater-item-604093f\" colspan=\"1\" rowspan=\"1\">Rated Insulation Level (kV)<\/th>\n<td class=\"elementor-repeater-item-b4de002\" colspan=\"1\" rowspan=\"1\">12\/28\/75<\/td>\n<td class=\"elementor-repeater-item-66618e6\" colspan=\"1\" rowspan=\"1\">24\/50\/125<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-127c401\">\n<th class=\"elementor-repeater-item-135a634\" colspan=\"1\" rowspan=\"1\">Rated Short Time Withstand Current for 3Sec. (kA)<\/th>\n<td class=\"elementor-repeater-item-f1f453e\" colspan=\"1\" rowspan=\"1\">26.3<\/td>\n<td class=\"elementor-repeater-item-f999901\" colspan=\"1\" rowspan=\"1\">26.3<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-7edd8b3\">\n<th class=\"elementor-repeater-item-b8acc06\" colspan=\"1\" rowspan=\"1\">Rated Short Circuit Breaking Capacity (kA)<\/th>\n<td class=\"elementor-repeater-item-290c75d\" colspan=\"1\" rowspan=\"1\">26.3<\/td>\n<td class=\"elementor-repeater-item-fd6c5ac\" colspan=\"1\" rowspan=\"1\">26.3<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-5150eb8\">\n<th class=\"elementor-repeater-item-ebfc2d2\" colspan=\"1\" rowspan=\"1\">Rated Short Circuit Making Capacity (kAp)<\/th>\n<td class=\"elementor-repeater-item-1b93754\" colspan=\"1\" rowspan=\"1\">65.75<\/td>\n<td class=\"elementor-repeater-item-e476f58\" colspan=\"1\" rowspan=\"1\">65.75<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-16ea52c\">\n<th class=\"elementor-repeater-item-c1c640d\" colspan=\"1\" rowspan=\"1\">Closing Time<\/th>\n<td class=\"elementor-repeater-item-f845ae5\" colspan=\"1\" rowspan=\"1\">&lt; 60ms<\/td>\n<td class=\"elementor-repeater-item-a7d9a75\" colspan=\"1\" rowspan=\"1\">&lt; 60ms<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-a27cdf3\">\n<th class=\"elementor-repeater-item-70a96a5\" colspan=\"1\" rowspan=\"1\">Opening Time<\/th>\n<td class=\"elementor-repeater-item-6e5bd45\" colspan=\"1\" rowspan=\"1\">&lt; 40ms<\/td>\n<td class=\"elementor-repeater-item-2688f5d\" colspan=\"1\" rowspan=\"1\">&lt; 40ms<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-eddee58\">\n<th class=\"elementor-repeater-item-13144d4\" colspan=\"1\" rowspan=\"1\">Rated Operating Sequence<\/th>\n<td class=\"elementor-repeater-item-e44d9e3\" colspan=\"1\" rowspan=\"1\">0-300ms-CO-3 min.-CO<\/td>\n<td class=\"elementor-repeater-item-e747e75\" colspan=\"1\" rowspan=\"1\">0-300ms-CO-3 min.-CO<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-83ba74e\">\n<th class=\"elementor-repeater-item-98ef03f\" colspan=\"1\" rowspan=\"1\">Rated Mechanical Life<\/th>\n<td class=\"elementor-repeater-item-0d90bab\" colspan=\"1\" rowspan=\"1\">20000 Operations<\/td>\n<td class=\"elementor-repeater-item-1a3a14d\" colspan=\"1\" rowspan=\"1\">20000 Operations<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-b66193d\">\n<th class=\"elementor-repeater-item-8d12726\" colspan=\"1\" rowspan=\"1\">Rated Electrical Life at Rated Current<\/th>\n<td class=\"elementor-repeater-item-464348f\" colspan=\"1\" rowspan=\"1\">20000 Operations<\/td>\n<td class=\"elementor-repeater-item-b2c30df\" colspan=\"1\" rowspan=\"1\">20000 Operations<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-bf35862\">\n<th class=\"elementor-repeater-item-5fe00ea\" colspan=\"1\" rowspan=\"1\">Rated Electrical Life at Rated Short Circuit Breaking Current<\/th>\n<td class=\"elementor-repeater-item-ded84c7\" colspan=\"1\" rowspan=\"1\">100 operations<\/td>\n<td class=\"elementor-repeater-item-9ae1e03\" colspan=\"1\" rowspan=\"1\">100 operations<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-221878c\">\n<th class=\"elementor-repeater-item-fdaabc8\" colspan=\"1\" rowspan=\"1\">Type of Operating Mechanism<\/th>\n<td class=\"elementor-repeater-item-806adab\" colspan=\"1\" rowspan=\"1\">Magnetic Actuator<\/td>\n<td class=\"elementor-repeater-item-859cf7f\" colspan=\"1\" rowspan=\"1\">Magnetic Actuator<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-1211ca2\">\n<th class=\"elementor-repeater-item-cd7fc2b\" colspan=\"1\" rowspan=\"1\">IP Grade of Switching Unit<\/th>\n<td class=\"elementor-repeater-item-3ac5c9c\" colspan=\"1\" rowspan=\"1\">IP65<\/td>\n<td class=\"elementor-repeater-item-a42e38a\" colspan=\"1\" rowspan=\"1\">IP65<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-7626d3d\">\n<th class=\"elementor-repeater-item-c264662\" colspan=\"1\" rowspan=\"1\">IP Grade of Control Cabinet<\/th>\n<td class=\"elementor-repeater-item-e4ef92a\" colspan=\"1\" rowspan=\"1\">IP65<\/td>\n<td class=\"elementor-repeater-item-dc74f3f\" colspan=\"1\" rowspan=\"1\">IP65<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-f489019\">\n<th class=\"elementor-repeater-item-b841e52\" colspan=\"1\" rowspan=\"1\">ON\/OFF Indication<\/th>\n<td class=\"elementor-repeater-item-de5e7d2\" colspan=\"1\" rowspan=\"1\">Both Mechanical &amp; Electrical<\/td>\n<td class=\"elementor-repeater-item-c410574\" colspan=\"1\" rowspan=\"1\">Both Mechanical &amp; Electrical<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-e63c73f\">\n<th class=\"elementor-repeater-item-c22137c\" colspan=\"1\" rowspan=\"1\">Applicable Standard<\/th>\n<td class=\"elementor-repeater-item-ee94e79\" colspan=\"1\" rowspan=\"1\">IS\/IEC 62271-100 &amp; IS\/IEC 60529<\/td>\n<td class=\"elementor-repeater-item-2676e41\" colspan=\"1\" rowspan=\"1\">IS\/IEC 62271-100 &amp; IS\/IEC 60529<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-abc816c\">\n<th class=\"elementor-repeater-item-b263ec7\" colspan=\"1\" rowspan=\"1\">Auxiliary Voltage<\/th>\n<td class=\"elementor-repeater-item-5c70728\" colspan=\"1\" rowspan=\"1\">24V DC &amp; 23OV AC<\/td>\n<td class=\"elementor-repeater-item-260d419\" colspan=\"1\" rowspan=\"1\">24V DC &amp; 23OV AC<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-bc0b418\">\n<th class=\"elementor-repeater-item-e95fcee\" colspan=\"1\" rowspan=\"1\">Auxiliary Voltage Tolerance<\/th>\n<td class=\"elementor-repeater-item-36522ec\" colspan=\"1\" rowspan=\"1\">85% to 110%<\/td>\n<td class=\"elementor-repeater-item-ee3aa86\" colspan=\"1\" rowspan=\"1\">85% to 110%<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-027cf9b\">\n<th class=\"elementor-repeater-item-5fadb16\" colspan=\"1\" rowspan=\"1\">Manual Trlp Operation<\/th>\n<td class=\"elementor-repeater-item-e4fbb76\" colspan=\"1\" rowspan=\"1\">Possible<\/td>\n<td class=\"elementor-repeater-item-e938f80\" colspan=\"1\" rowspan=\"1\">Possible<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-f7e4eff\">\n<th class=\"elementor-repeater-item-d060ef9\" colspan=\"1\" rowspan=\"1\">Type of Insulation<\/th>\n<td class=\"elementor-repeater-item-4b08f8d\" colspan=\"1\" rowspan=\"1\">Solid Dielectric<\/td>\n<td class=\"elementor-repeater-item-0a2a212\" colspan=\"1\" rowspan=\"1\">Solid Dielectric<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-a94637d\">\n<th class=\"elementor-repeater-item-12c1ef6\" colspan=\"1\" rowspan=\"1\">Aux. Contacts<\/th>\n<td class=\"elementor-repeater-item-3120c31\" colspan=\"1\" rowspan=\"1\">4 N.O. + 4 N.C. in each of the 2 positions<\/td>\n<td class=\"elementor-repeater-item-b9d4293\" colspan=\"1\" rowspan=\"1\">4 N.O. + 4 N.C. in each of the 2 positions<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-ee6024c\">\n<th class=\"elementor-repeater-item-0d46fab\" colspan=\"1\" rowspan=\"1\">SCADA Compatible<\/th>\n<td class=\"elementor-repeater-item-afc05c9\" colspan=\"1\" rowspan=\"1\">YES<\/td>\n<td class=\"elementor-repeater-item-b323c22\" colspan=\"1\" rowspan=\"1\">YES<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c7dd25f elementor-section-stretched elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" data-id=\"c7dd25f\" data-element_type=\"section\" data-settings=\"{\">\n<div class=\"elementor-container elementor-column-gap-default\">\n<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9fd54de\" data-id=\"9fd54de\" data-element_type=\"column\" data-settings=\"{\">\n<div class=\"elementor-widget-wrap elementor-element-populated\">\n<div class=\"elementor-element elementor-element-e3b0b64 elementor-widget elementor-widget-sina_table\" data-id=\"e3b0b64\" data-element_type=\"widget\" data-widget_type=\"sina_table.default\">\n<div class=\"elementor-widget-container\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<p>\n<\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-459683 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-884926 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-613208\">\n\t<a class=\"kc_button\" href=\"http:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/3-PHASE-TO-2-PHASE-pdf-vans.pdf\" target=\"_blank\" title=\"http:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/railway-outdoor-vans.pdf\" onclick=\"\">\n\t\tDownload Brochure\t<\/a>\n<\/div>\n<div class=\"kc-elm kc-css-247849\" style=\"height: 74px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/973"}],"collection":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/comments?post=973"}],"version-history":[{"count":34,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/973\/revisions"}],"predecessor-version":[{"id":1554,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/973\/revisions\/1554"}],"wp:attachment":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/media?parent=973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}