{"id":976,"date":"2022-10-04T13:51:53","date_gmt":"2022-10-04T13:51:53","guid":{"rendered":"https:\/\/vanselectroengineerings.com\/?page_id=976"},"modified":"2022-10-18T16:11:36","modified_gmt":"2022-10-18T16:11:36","slug":"vacuum-contactors-and-special-products","status":"publish","type":"page","link":"https:\/\/vanselectroengineerings.com\/index.php\/vacuum-contactors-and-special-products\/","title":{"rendered":"VACUUM CONTACTORS AND SPECIAL PRODUCTS"},"content":{"rendered":"<p><section class=\"kc-elm kc-css-540164 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-581983 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-631999 kc_text_block\"><\/p>\n<p><strong>VACUUM CONTACTORS AND SPECIAL PRODUCTS<\/strong><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-942173\" style=\"height: 20px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-907121 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-521198 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-967306 kc_text_block\"><\/p>\n<p><strong>VACUUM CONTACTORS<\/strong><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-230061 kc_text_block\"><\/p>\n<p>\u2022 Available in 1.5kV\/3.6kV\/7.2kV\/12kV\/36kV ratings<br \/>\n\u2022 Available in 200A, 400A &amp; 630A Ratings<br \/>\n\u2022 Electrically or Mechanically Latched<br \/>\n\u2022 Available in fixed or in draw-out version<br \/>\n\u2022 With or without back-up HT HRC Fuse<br \/>\n\u2022 High Frequency of Switching Very High Mechanical Life<br \/>\n\u2022 Very High Electrical Life<br \/>\n\u2022 Flexible Control Voltage<br \/>\n\u2022 Compact &amp; Light Weight<br \/>\n\u2022 Robust<br \/>\n\u2022 Shock Resistant<br \/>\n\u2022 Suitable for frequent switching applications<br \/>\n\u2022 Suitable for Motor Switching (AC-3 &amp; AC-4)<br \/>\n\u2022 Suitable for Capacitor Switching<br \/>\n\u2022 Complies with IS\/IEC 62271-106<\/p>\n<p>\n<\/div><\/div><\/div><div class=\"kc-elm kc-css-238866 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-1166\" style=\"height: 20px; clear: both; width:100%;\"><\/div><div class=\"kc-elm kc-css-385766 kc_shortcode kc_single_image\">\n\n        <img src=\"https:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/Screenshot-2022-10-07-123446.png\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-536655 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-497370 kc_column kc_col-sm-12\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-593559 kc_text_block\"><\/p>\n<p class=\"elementor-heading-title elementor-size-default\"><strong>Guaranteed Technical Particulars<\/strong><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-285840 kc_text_block\"><\/p>\n<table>\n<thead>\n<tr>\n<th class=\"elementor-repeater-item-71558f7\" colspan=\"1\">Parameter<\/th>\n<th class=\"elementor-repeater-item-fafbbc0\" colspan=\"1\">15kV<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"elementor-repeater-item-aaee6c0\">\n<th class=\"elementor-repeater-item-07d58cf\" colspan=\"1\" rowspan=\"1\">Type<\/th>\n<td class=\"elementor-repeater-item-5d344c8\" colspan=\"1\" rowspan=\"1\">BSV 15<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-ba66086\">\n<th class=\"elementor-repeater-item-dd615b4\" colspan=\"1\" rowspan=\"1\">Rated Voltage (kV)<\/th>\n<td class=\"elementor-repeater-item-65a0ac4\" colspan=\"1\" rowspan=\"1\">15<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-cf9a312\">\n<th class=\"elementor-repeater-item-adbcd46\" colspan=\"1\" rowspan=\"1\">Rated Frequency (Hz.)<\/th>\n<td class=\"elementor-repeater-item-135d022\" colspan=\"1\" rowspan=\"1\">50\/60<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-27d918e\">\n<th class=\"elementor-repeater-item-48da52a\" colspan=\"1\" rowspan=\"1\">Rated Operational Current (A)<\/th>\n<td class=\"elementor-repeater-item-d2fd0a3\" colspan=\"1\" rowspan=\"1\">400<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-ff57c09\">\n<th class=\"elementor-repeater-item-607475d\" colspan=\"1\" rowspan=\"1\">Rated Lightning Impulse Withstand Voltage (kVp)<\/th>\n<td class=\"elementor-repeater-item-45feed8\" colspan=\"1\" rowspan=\"1\">95<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-ecf5628\">\n<th class=\"elementor-repeater-item-1c791a3\" colspan=\"1\" rowspan=\"1\">Rated One Minute Power Frequency Withstand Voltage (kV)<\/th>\n<td class=\"elementor-repeater-item-5e9bc36\" colspan=\"1\" rowspan=\"1\">38<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-a82922f\">\n<th class=\"elementor-repeater-item-6cef8c9\" colspan=\"1\" rowspan=\"1\">Rated Short Time Withstand Current (kA)<\/th>\n<td class=\"elementor-repeater-item-41370bd\" colspan=\"1\" rowspan=\"1\">6<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-1007f5b\">\n<th class=\"elementor-repeater-item-604093f\" colspan=\"1\" rowspan=\"1\">Rated Short Time Withstand Duration (Sec.)<\/th>\n<td class=\"elementor-repeater-item-e383912\" colspan=\"1\" rowspan=\"1\">1<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-b5f3828\">\n<th class=\"elementor-repeater-item-9c83745\" colspan=\"1\" rowspan=\"1\">Rated Making Capacity (A)<\/th>\n<td class=\"elementor-repeater-item-f502cf7\" colspan=\"1\" rowspan=\"1\">4000<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-4bcf34f\">\n<th class=\"elementor-repeater-item-6f791b6\" colspan=\"1\" rowspan=\"1\">Rated Breaking Capacity (A)<\/th>\n<td class=\"elementor-repeater-item-0ab9857\" colspan=\"1\" rowspan=\"1\">3200<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-bc9c50d\">\n<th class=\"elementor-repeater-item-05d41b6\" colspan=\"1\" rowspan=\"1\">Operating Frequency<\/th>\n<td class=\"elementor-repeater-item-5e15cba\" colspan=\"1\" rowspan=\"1\">120 Cycles\/Hour<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-d898c3f\">\n<th class=\"elementor-repeater-item-b7c1609\" colspan=\"1\" rowspan=\"1\">Mechanical Life<\/th>\n<td class=\"elementor-repeater-item-3012d10\" colspan=\"1\" rowspan=\"1\">300000 Operations<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-1f429a5\">\n<th class=\"elementor-repeater-item-bea8c92\" colspan=\"1\" rowspan=\"1\">Electrical Life<\/th>\n<td class=\"elementor-repeater-item-08242b0\" colspan=\"1\" rowspan=\"1\">200000 Operations<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-9c4e6b4\">\n<th class=\"elementor-repeater-item-65512be\" colspan=\"1\" rowspan=\"1\">Rated Control Voltage<\/th>\n<td class=\"elementor-repeater-item-1d7ed19\" colspan=\"1\" rowspan=\"1\">110\/220 Vdc<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-e3962c9\">\n<th class=\"elementor-repeater-item-96bcecd\" colspan=\"1\" rowspan=\"1\">Aux. Contacts<\/th>\n<td class=\"elementor-repeater-item-a89bd7b\" colspan=\"1\" rowspan=\"1\">2N.O. + 2N.C<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-a8af033\">\n<th class=\"elementor-repeater-item-f132ee5\" colspan=\"1\" rowspan=\"1\">Type of LLatching Mechanism<\/th>\n<td class=\"elementor-repeater-item-1fc7d79\" colspan=\"1\" rowspan=\"1\">Electrical<\/td>\n<\/tr>\n<tr class=\"elementor-repeater-item-0cd5486\">\n<th class=\"elementor-repeater-item-3c30325\" colspan=\"1\" rowspan=\"1\">Applicable Standard<\/th>\n<td class=\"elementor-repeater-item-229821e\" colspan=\"1\" rowspan=\"1\">IEC 62271-106<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n<\/div><div class=\"kc-elm kc-css-4041\" style=\"height: 49px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-177185 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-263814 kc_col-sm-12 kc_column kc_col-sm-12\"><div class=\"kc-col-container\">\n<div class=\"kc-elm kc-css-119980\">\n\t<a class=\"kc_button\" href=\"http:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/VACUUM-CONTACTORS-pdf-vans-Copy.pdf\" target=\"_blank\" title=\"http:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/railway-outdoor-vans.pdf\" onclick=\"\">\n\t\tDownload Brochure\t<\/a>\n<\/div>\n<div class=\"kc-elm kc-css-11606\" style=\"height: 74px; clear: both; width:100%;\"><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"kc-elm kc-css-909109 kc_row\"><div class=\"kc-row-container  kc-container\"><div class=\"kc-wrap-columns\"><div class=\"kc-elm kc-css-52908 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-467053 kc_text_block\"><\/p>\n<p><strong>SPECIAL PRODUCTS:<\/strong><\/p>\n<p>\n<\/div><div class=\"kc-elm kc-css-479776 kc_text_block\"><\/p>\n<p>\u2022 15kV, 1200A, 31.5kA VCB to IEEE\/ANSI Standards<br \/>\n\u2022 15kV, 2000A, 40kA VCB to IEEE\/ANSI Standards<br \/>\n\u2022 15kV, 4000A, 63kA VCB to IEEE\/ANSI Standards<br \/>\n\u2022 27kV, 1250A, 25\/31.5kA VCB to IEEE\/ANSI Standards<br \/>\n\u2022 38kV, 1250A, 25\/31.5kA VCB to IEEE\/ANSI Standards<br \/>\n\u2022 15kV, 800A, 16kA Vacuum Auto Reclosers to IEEE\/ANSI Standards<br \/>\n\u2022 38kV, 800A, 16kA Vacuum Auto Reclosers to IEEE\/ANSI Standards<br \/>\n\u2022 52kV Class VCB for Traction Power Supply<br \/>\n\u2022 Control &amp; Relay Panels (Indoor\/Outdoor)<br \/>\n\u2022 Switchgear for Test Laboratories like CPRI<br \/>\n\u2022 MV Switchgear for any Special Applications<\/p>\n<p>\n<\/div><\/div><\/div><div class=\"kc-elm kc-css-761967 kc_col-sm-6 kc_column kc_col-sm-6\"><div class=\"kc-col-container\"><div class=\"kc-elm kc-css-269650\" style=\"height: 10px; clear: both; width:100%;\"><\/div><div class=\"kc-elm kc-css-93427 kc_shortcode kc_single_image\">\n\n        <img src=\"https:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/Screenshot-2022-10-07-125542-1.png\" class=\"\" alt=\"\" \/>    <\/div>\n<div class=\"kc-elm kc-css-230178 kc_shortcode kc_single_image\">\n\n        <img src=\"https:\/\/vanselectroengineerings.com\/wp-content\/uploads\/2022\/10\/Screenshot-2022-10-07-125542.png\" class=\"\" alt=\"\" \/>    <\/div>\n<\/div><\/div><\/div><\/div><\/section><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/976"}],"collection":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/comments?post=976"}],"version-history":[{"count":50,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/976\/revisions"}],"predecessor-version":[{"id":1555,"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/pages\/976\/revisions\/1555"}],"wp:attachment":[{"href":"https:\/\/vanselectroengineerings.com\/index.php\/wp-json\/wp\/v2\/media?parent=976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}